MoFlo Cell Sorter
670 Albany St., BioSquareIII, Rm 527Use SHIFT+ENTER to open the menu (new window).
The Dako MoFlo is a three laser, seven detector flow cytometer capable of sorting cells into two populations based on user specifications/gating. The MoFlo has one 488nm laser, a UV laser tuned to 351nm, and a red laser at 635nm. Like the FCCF FACScans, the MoFlo collects data for forward scatter, side scatter, Fl1 (530±30nm), Fl2 (585±42nm), and Fl3 (650±30nm) but also has detectors for three more channels which can be adjusted through the use of filters. MoFlo is capable of sorting cells into two distinct populations, either into tubes or into microtiter plates of any size from 6 to 96 wells. Single cell deposition is also possible.
Yanhui Deng
$80.00
$80.00
Schedule
L901 FACScan
72 East Concord St., Rm L901Use SHIFT+ENTER to open the menu (new window).
The L901 FACScan is a single laser, five detector analysis flow cytometer. The laser excites at 488nm and collects data for forward scatter, side scatter, Fl1 (530±30nm), Fl2 (585±42nm), and Fl3 (650±30nm), thus making it a three color analyzer. There is a MacG5 running the FACScan using BD Cellquest Pro v5.2 software. A MacG4, also running BD Cellquest Pro v5.2 software, serves as an analysis workstation and is not connected to the FACScan.
 
FCCF
$40.00
$60.00
Schedule
X620 FACScan
650 Albany St., X Building, Rm 620Use SHIFT+ENTER to open the menu (new window).
The X620 FACScan is a single laser, five detector analysis flow cytometer. The laser excites at 488nm and collects data for forward scatter, side scatter, Fl1 (530±30nm), Fl2 (585±42nm), and Fl3 (650±30nm), thus making it a three color analyzer. There is a MacG5 running the FACScan using BD Cellquest Pro v5.2 software. A MacG4, also running BD Cellquest Pro v5.2 software, serves as an analysis workstation and is not connected to the FACScan.
 
FCCF
$40.00
$60.00
Schedule
LSRII
670 Albany St., BioSquareIII, Rm528Use SHIFT+ENTER to open the menu (new window).
The LSRII is a four laser, 13 detector analysis flow cytometer capable of detecting 11 colors simultaneously. We have a "Blue" (488nm) laser, a "UV" (355nm) laser, a "Red" (633nm) laser, and a "Violet" (405) laser. This unit also features a high throughput 96 well autosampler. Digital acquisition increases sampling rates compared to analog machines. The acquisition workstation is a PC running FACS Diva 6.0. The data files can be batch converted for analysis using other applications such as Summit, CellQuest Pro, and WinMDI to name a few.
FCCF
$45.00
$67.50
Schedule
FACSCalibur
72 East Concord St., Rm L508AUse SHIFT+ENTER to open the menu (new window).
The FCCF FACSCalibur is a single laser, five detector analysis flow cytometer. The laser excites at 488nm and collects data for forward scatter, side scatter, Fl1 (530±30nm), Fl2 (585±42nm), and Fl3 (650±30nm). There is a Mac computer running the FACSCalibur using BD Cellquest Pro v5.2 software.
FCCF
$40.00
$60.00
Schedule
L508A FACScan
72 East Concord St., Rm L508AUse SHIFT+ENTER to open the menu (new window).
The L508A FACScan is a single laser, five detector analysis flow cytometer. The laser excites at 488nm and collects data for forward scatter, side scatter, Fl1 (530±30nm), Fl2 (585±42nm), and Fl3 (650±30nm), thus making it a three color analyzer. There is a MacG5 running the FACScan using BD Cellquest Pro v5.2 software. A MacG4, also running BD Cellquest Pro v5.2 software, serves as an analysis workstation and is not connected to the FACScan.
FCCF
$40.00
$60.00
Schedule